Wood Joists
Check a floor or roof joist of one to four spans, with optional overhangs, using the NDS bending, shear, bearing, and deflection provisions. Loads are entered for the joist spacing you choose, the repetitive-member factor is available, and a roof joist can be given a slope. The analysis, design checks, and Design button work as they do in Wood Beam.
Quick start
- Add a Wood Joists calculation and enter a description.
- Choose Floor or Roof. For a roof joist, choose the roof slope.
- Select ASD or LRFD.
- Enter the span lengths in feet. Use Add and Remove for up to four spans, and enter any overhangs.
- Choose the joist spacing and the number of plies.
- Select the lumber type, then the size, species, and grade (or the glulam combination or engineered product).
- Open the NDS Factors page and make every factor selection that applies.
- Open Loads and Combinations, enter the loads, and review the combinations.
- Use Bracing Locations where needed, enter the deflection limits, and click Run Model. Review the results and print the report.
Geometry, use, and roof slope
Span lengths and overhangs are entered in feet, and the total length must not exceed 99.99 ft. All supports are pinned.
Floor and Roof set the starting deflection limits: floor L/240 total-load and L/360 live-load, roof L/180 total-load and L/240 live-load. Each use keeps its own limits, and you can edit either limit.
For a roof joist, choose a slope from the Slope list, or choose Other and type the rise per 12 inches of run, from 0.0 to 16.0. The slope is not used for a floor joist. Span and overhang lengths are entered as horizontal plan lengths. The module converts them to the actual sloped length for the analysis, bracing, and design.
Spacing and plies
Choose a joist spacing of 12, 16, 24, or 32 inches, or choose Other and type the spacing in inches. The module analyzes one joist. Loads entered as area loads (psf) are converted to a line load on that joist using the spacing, and changing the spacing updates those loads.
Plies (1 to 4) are identical joists side by side that act together. Area, section modulus, stiffness, and self-weight are multiplied by the number of plies.
Show results in lb displays the forces and reactions in pounds. Clear it to display them in kips.
Lumber type and size
The Lumber list offers four member types:
- Conventional: sawn lumber. Choose the nominal size, species, and grade.
- Glulam and Glulam SP: western and Southern Pine glulam.
- Engineered: Parallam PSL, Microllam LVL, and Versa-Lam LVL products, for dry-use conditions.
The Design Values page shows the reference values for the selected member. Favorite lumber chosen in Options is listed first and marked with a star. Joists are checked for bending about the strong axis only.
NDS adjustment factors and the repetitive factor
The NDS Factors page holds the moisture, temperature, and incising selections, Top Edge Fully Braced, Shear at d, and Use Cb for bearing. For LRFD it also holds Live load use and Treated member, which set the time effect factor λ. When you click Run Model, any required selection that is still empty is shown in gold.
The Repetitive Factor check box applies the repetitive-member factor Cr to the bending value. The check box shows the factor that applies to the selected member:
- 1.15 for NDS Table 4A or 4B sawn lumber 2 to 4 inches thick.
- 1.04 for structural composite lumber.
- No factor for any other member, such as glulam or other sawn sizes. The check box is then unavailable.
Cr applies only at a spacing of 24 inches or less. At a wider spacing the check box is unavailable and the factor is 1.00.
Each load combination receives its own time effect factor, CD for ASD or λ for LRFD, and calculations follow NDS 2024.
Loads and combinations
Open Loads and Combinations to enter point, distributed, and trapezoidal loads and assign each a load category. Concentrated moments and soil loads (H) are not available for wood. Choose whether to include the joist’s own weight. The combinations follow ASCE 7-22 and IBC 2024.
For a roof joist with a slope above 4:12, the editor offers the roof live load reduction R2 of ASCE 7-22 Section 4.8.2. It shows the factor for the chosen slope, which is 1.2 − 0.05F for F from 4 to 12 and 0.6 at 12:12 or steeper. The reduction is applied only when you select it.
Linking loads from other members
Use Link Other Member in the Loads and Combinations editor to load this joist with a support reaction of another joist or beam in the same project (Wood Joists, Wood Beam, or Steel Beam), instead of typing the load.
- Click Link Other Member and choose the providing member from the list. The form runs that member and draws its supports.
- Select the support, R1, R2, and so on, in the list or by clicking it in the diagram. The reaction of each load case is shown below the diagram.
- Choose how the reaction is applied (below) and enter the location in feet or in feet and inches, for example
12 9. - Click Add.
- Point load (lb): offered when the providing member is a beam. The reaction becomes a point load at the location you enter.
- Point load (plf): offered when the providing member is a joist. The reaction is converted to plf with the providing joist’s spacing and stored as a per-spacing point load, so this joist multiplies it by its own spacing. For example, 100 lb at 16 in. is 75 plf, which is 150 lb on a joist at 24 in. spacing.
Each load case of the reaction (D, L, Lr, S, W, and so on) becomes its own load row of the same category, so this member’s own combinations apply. Uplift reactions transfer as negative loads. For live, roof live, and snow loads the largest downward reaction at the support is used. The rows are described as Linked from <name>, Support n, and the loading diagram marks them with * and the note * Linked load. Use Edit Link on a row to change the member, support, method, or location. Remove the row to remove the link.
The linked values are refreshed every time you click Run Model. The providing member is run first, even when it has no current results, and its own links are refreshed before it, so a chain of links stays current. If a providing member cannot be calculated, or no longer has the linked support or a reaction there, the run stops with a message that names it. Project Explorer shows (Linked to <name>) after the providing member’s name. A linked member cannot be deleted until the linked rows are removed, and circular links are refused.
A wood joist can also provide its reactions to other members.
Lateral bracing
The stability factor CL is calculated for every unbraced segment. The unbraced length runs between supports and braces that restrain the compression edge, which is the top in positive moment and the bottom in negative moment and at overhangs. Use Bracing Locations to describe the braces, or select Top Edge Fully Braced for a top edge restrained by sheathing. For a sloped joist, brace locations are measured along the sloped length. Slenderness RB must not exceed 50.
Results and checks
The results tabs show the Loading Diagram, V Diagram, M Diagram, Δ Diagram, Reactions, Design Calculations, Element Results, and Element Forces.
- Bending: every combination is checked in every unbraced segment.
- Shear: the maximum shear for each combination, at the support face or at d.
- Bearing: the required bearing length at each support, from NDS 3.10.2 and 3.10.4.
- Deflection: total-load deflection is compared with the total-load limit, and live-load deflection with the live-load limit.
Missing selections and invalid values stop the calculation with a specific message.
Design button
Design searches sizes for the lumber you choose. Each candidate receives the full Run Model checks: bending, shear, bearing, and both deflection limits. For each size group the results list the size that fails and the three lightest sizes that pass, ranked by cross-section area. Choose Use Size to load a size and run it.
Saving, reports, and scope
Save the project to retain the inputs and report selections. Run the model after reopening and before printing. Use Report Options to choose the diagrams, flexure and shear tables, deflection checks, and FEA information.
The module checks one joist with simple supports. It does not check connections, notches or holes, creep, wind deflection, or load sharing between joists beyond the repetitive factor, and it does not design the supporting members. Verify that the selected provisions and assumptions apply to your project.