Wood Beam

Wood Beam

Check a wood beam of one to four spans, with optional overhangs, using the NDS bending, shear, bearing, and deflection provisions. The module analyzes the beam with a finite-element model, designs it for ASD or LRFD, and can search sizes for you with the Design button. It also includes a Hip / Valley Beam option for roof beams.

Quick start

  1. Add a Wood Beam calculation and enter a description.
  2. Choose Floor or Roof, then select ASD or LRFD.
  3. Enter the span lengths in feet. Use Add and Remove for up to four spans, and enter the left and right overhangs if the beam has them.
  4. Select the lumber type, then the size, species, and grade (or the glulam combination or engineered product).
  5. Open the NDS Factors page and make every factor selection that applies.
  6. Open Loads and Combinations, enter the loads, and review the combinations.
  7. Use Bracing Locations when the compression edge is not fully braced, and enter the total-load and live-load deflection limits.
  8. Click Run Model. Review the diagrams, reactions, and design calculations, then print the report.

Geometry and member use

Span lengths and overhangs are entered in feet. The total length, including both overhangs, must not exceed 99.99 ft. Every support is modeled as pinned, so the beam is simply supported or continuous over its interior supports.

Floor and Roof set the starting deflection limits: floor L/240 total-load and L/360 live-load, roof L/180 total-load and L/240 live-load. Each use keeps its own limits, so changing the limits for a roof beam does not change the floor values, and you can edit either limit at any time.

If an overhang is longer than one-quarter of the adjacent span, Run Model shows a Cantilever Ratio Exceeded message that cites IRC R507.5.1, which applies to deck beams. Choose Continue to run the calculation anyway, or Cancel to change the geometry. The check does not apply to engineered lumber or to hip and valley beams.

Lumber type and size

The Lumber list offers four member types:

  • Conventional: sawn lumber. Choose the nominal size, species, and grade. The available grades depend on the size class.
  • Glulam and Glulam SP: western and Southern Pine glulam. Choose the size and the combination symbol.
  • Engineered: Parallam PSL, Microllam LVL, and Versa-Lam LVL products. These products are for dry-use conditions.

The Design Values page shows the reference values for the selected member. Favorite lumber chosen in Options is listed first and marked with a star. Click the section picture to see the section properties.

Plies (1 to 4) are offered for 2x sawn lumber only. Plies act together as identical members side by side, so area, section modulus, stiffness, and self-weight are multiplied by the number of plies.

Minor Axis checks bending about the weak axis, with the load applied to the wide face. It is not available for Versa-Lam, whose published values cover beam orientation only.

NDS adjustment factors

The NDS Factors page holds the selections that set the adjusted design values:

  • Moisture, temperature, and incising conditions. The moisture choices differ for sawn lumber and for glulam or engineered lumber.
  • Top Edge Fully Braced, for a compression edge that is continuously restrained, for example by sheathing.
  • Shear at d, which checks shear at a distance d from the support face instead of at the face.
  • Use Cb for bearing, which applies the bearing area factor Cb of NDS 3.10.4 in the bearing check.
  • For LRFD only: Live load use and Treated member, which set the time effect factor λ.

When you click Run Model, any factor selection that is required and still empty is shown in gold and the NDS Factors page is brought forward.

Each load combination receives its own time effect factor: CD for ASD (dead 0.9, floor live 1.0, snow 1.15, roof live 1.25, wind and seismic 1.6, rain 1.0) or λ for LRFD. Stability, size, flat-use, and format-conversion factors are applied as the NDS requires for the selected member type.

Loads and combinations

Open Loads and Combinations to enter point, distributed, and trapezoidal loads and assign each a load category. Loads are entered in lb, plf, psf, and lb-ft as the editor shows. Concentrated moments and soil loads (H) are not available for a wood beam. Choose whether to include the beam’s own weight, which the module calculates from the section area and the material density.

The combinations follow ASCE 7-22 and IBC 2024. The editor also offers a seismic Ω0 overstrength check. When it is selected, the check uses the Ω0Ev point loads you enter and the SDS value from Project Settings → Site Information, so enter SDS there before running.

Lateral bracing

Beam stability factor CL is calculated for every unbraced segment of the compression edge. The unbraced length runs between supports and braces that restrain that edge. Use Bracing Locations to describe the brace layout, in an editor like the Steel Beam one, or select Top Edge Fully Braced on the NDS Factors page. The effective length comes from NDS Table 3.3.3, and slenderness RB must not exceed 50.

A negative-moment region is checked against the opposite edge, because a brace on the tension side does not stabilize it.

Hip / Valley Beam

Hip / Valley Beam is available for roof beams only. Check Hip / Valley Beam and open Beam Layout to choose Hip or Valley and enter:

  • The plan rafter run and the plan overhang, in feet. A valley beam cannot have an overhang.
  • The roof slope, in inches of rise per 12 inches of run.
  • The dead, roof live, snow, and wind loads, in psf.

The module converts the plan dimensions to actual beam lengths with the length factor K1 = √(2 + (s/12)²). It then generates the line loads: dead load uses the roof surface area, roof live and snow loads use the plan projection, and wind acts normal to the beam. The horizontal thrust from wind at the pin support is reported. The Design Calculations page lists each of these steps.

The generated loads cannot be edited in the Loads editor. In this mode the beam is checked about its major axis, with the compression edge braced, with self-weight included, and with shear checked at the support face. A kind of load left at zero is dropped from the combinations. Clearing the check box restores the ordinary beam inputs you had before.

Design button

Design searches member sizes for you. Choose the type of lumber, then the species and grade (sawn), the glulam combination, or the engineered product. For sawn lumber, tick the nominal-thickness groups to search. Each candidate receives the full Run Model checks: bending, shear, bearing, and both deflection limits.

The results list, for each size group, the size that fails and the three lightest sizes that pass, ranked by cross-section area. Choose Use Size to load a size into the beam and run it. Sawn sizes that the NDS does not list for the chosen species and grade are skipped. The cantilever ratio message is shown when you run the chosen size.

Results and checks

The results tabs show the Loading Diagram, V Diagram, M Diagram, Δ Diagram, Reactions, Design Calculations, Element Results, and Element Forces. Diagrams show the load combination chosen in the combination list.

  • Bending: every combination is checked in every unbraced segment, with the positive and negative moments each checked on their own compression edge.
  • Shear: the maximum shear for each combination, at the support face or at d.
  • Bearing: the required bearing length at each support, from NDS 3.10.2 and 3.10.4.
  • Deflection: total-load deflection (dead plus live or roof load) is compared with the total-load limit. Live, roof live, snow, and rain deflection is compared with the live-load limit. Wind deflection is not checked.

Calculations follow NDS 2024. Review the Design Calculations tab for the factors used in each check. Section sizes the NDS does not list, missing selections, and invalid values stop the calculation with a specific message.

Saving, reports, and scope

Save the project to retain the inputs and report selections. Run the model after reopening and before printing. Use Report Options to choose the deflection diagrams, the flexure and shear tables, the deflection checks, and the FEA information. The report prints the governing combinations by default. The print-calculations button on the input page prints the detailed Design Calculations page after a successful run.

The module does not check connections, notches or holes, creep, curved or tapered glulam, wind deflection, or the repetitive-member factor Cr, and it does not design the supporting members. Engineered lumber is for dry-use conditions. Verify that the selected provisions and assumptions apply to your project.