Loading / Design Criteria

Loading / Design Criteria

Record the dead and live loads used on a project and, if you choose, the site seismic and wind criteria, and print them as a project loading sheet. This is a documentation module. It performs no structural analysis, and other calculations do not read its values.

Quick start

  1. Add a Loading / Design Criteria calculation and enter a description.
  2. Enter a heading for the first load table, for example a roof, floor, or wall assembly.
  3. Click Add at the bottom of the item list. Enter the item name and its weight in psf for each component.
  4. Enter the live load for the assembly in psf.
  5. Use Duplicate to copy a table when another assembly is similar, and edit the copy.
  6. To include the site criteria, click ASCE Loads.
  7. Choose Run Model to check the entries, then print the report.

Load tables

Each load table lists the items that make up an assembly, such as roofing, sheathing, framing, insulation, and ceiling. For each item, enter a name and its weight in psf. Clear the Print box on an item to leave it out of the total and the printed table.

The table shows the Total Dead Load of the items marked to print, and a separate Live Load entry. Weights and live loads must be from 0.0 to 999.0 psf, and the total dead load must not exceed 999.0 psf. The total shows Invalid until every entry is a valid number.

You can keep several tables in one calculation. Duplicate makes a copy, Delete removes a table you added after confirmation, and ✥ Move lets you drag a table to a new position. Each table has its own Print check box, so a table can be kept in the calculation without appearing in the report.

ASCE site criteria

ASCE Loads opens the Project Site information, where the latitude, longitude, risk category, site class, wind speed, and the seismic values Ss, S1, SDS, SD1, and TL are kept for the project. The same values are used by the other modules that need them.

When the site criteria are included in this calculation, the report adds an ASCE 7-22 Lateral Analysis Design Criteria table. Any value that has not been entered prints as Not provided. Confirm that the site data applies to your project site.

Default values

Save As Default stores the current tables as the starting point for new Loading / Design Criteria calculations on your computer. The description is not saved with the defaults. Defaults do not change calculations that already exist.

Saving, reports, and scope

Save the project to retain the tables. Run Model checks the entries and confirms that the report is available. It does not calculate anything. The report prints each table marked to print, with its items, total dead load, and live load, followed by the site criteria when they are included.

The module does not calculate loads from the building geometry, apply load combinations, or send values to other calculations. Enter the loads for each member in that member’s own Loads and Combinations editor.